With e-Pal, you never learn alone
Technical Training. Digital Delivery. Recognized Results.
We don’t sell courses. We deliver outcomes
Industrial Automation
Siemens Process Control Basics
Category 100: System Overview 1
Course 110: PCS 7 SYSTEM ARCHITECTURE
- Module 111: A typical system configuration [PCS 7 Multiproject, Master Data Library, Plant Hierarchy, Process Object View, Client-Server Architecture, OS Server Redundancy, Single Station, Distribution of PCS 7 applications, Reference Architecture]
- Module 112: ES: Engineering Station [SIMATIC Manager, Component View vs Plant View, Continuous Function Chart (CFC), Sequential Function Chart (SFC), S7-SCL, IEA Import/Export Assistant, Version Trail, VT, Version Cross Manager]
- Module 113: AS: Automation Station [S7-400H, CPU 410-5H, CPU 410E, Rack UR2, PS 407, CP 443-1, H-System, Sync Modules, Memory Card, Firmware Update, Process Image, Cycle Time]
- Module 114: Field devices [PROFIBUS DP, PROFIBUS PA, PROFINET IO, ET 200M, ET 200iSP, ET 200SP HA, HART Protocol, SIMATIC PDM, Y-Link, DP/PA Coupler, Active Field Distributor, AFD, CFU]
- Module 115: PCS 7 OS: Operator Station [WinCC Explorer, Graphics Designer, OS Project Editor, Server Data, User Administrator, Lifebeat Monitoring, Time Synchronization, Faceplates, Block Icons, OS Single Station]
- Module 116: Plant bus and terminal bus [Industrial Ethernet, ISO Protocol, TCP/IP, SCALANCE Switches, OSM/ESM, Ring Topology, Redundant Ring, BCE, CP 1623, CP 1628, MAC Address, IP Address]
- Module 117: From engineering to process operation [NetPro, Named Connections, AS Download, OS Compile, OS Download, Change Control, Compile and Download, Runtime Activation, Check Consistency]
Course 120: PCS 7 SOFTWARE SYSTEM
- Module 121: Basic data [Master Data Library, Process Tag Types, Models, Shared Declarations, Enumerations, Units, Equipment Modules, Control Module Types, CMT, EMT, PCS 7 Basic Library, Advanced Process Library (APL)]
- Module 122: Software licensing [Automation License Manager, ALM, Floating License, Single License, Rental License, Trial License, Process Objects, PO Count, AS Process Objects, OS Process Objects, Cumulative Licenses]
Category 200: SIMATIC Manager 2
Course 210: INTRODUCTION
Course 220: GLOBAL SETTINGS IN SIMATIC MANAGER
- Module 221: Language and Mnemonics [SIMATIC Manager Regional Settings, IEC 61131-3, Mnemonics English/German, STEP 7 Language, Display Language]
- Module 222: User project and library location [Storage Path, Default Location, Global Library, User Project, Multi-user engineering path]
- Module 223: Settings for archiving [PKZip, ARJ, LZH, Archive Options, Retrieve Options, Span across multiple disks, Compression rate]
- Module 224: Message number range [Message Number Assignment, CPU-wide unique numbers, Project-wide unique numbers, Alarm Logging numbering]
Course 230: PROJECT START
- Module 231: Wizard 'New Project' [PCS 7 New Project Wizard, Automatic Hierarchy, AS/OS insertion, Master Data Library creation]
- Module 232: Creating a project [Manual project creation, Insert New Object, Simatic PC Station, Simatic 400 Station, MPI address]
- Module 233: Expanding a multiproject [Insert into Multiproject, Remove from Multiproject, Cross-project engineering, Update Multiproject]
Course 240: PROJECT VIEWS AND OBJECTS
- Module 241: Plant view [Plant Hierarchy (PH), Hierarchy Folder, OS Area, HID (Higher Level Designation), Control Center, Picture Tree Manager]
- Module 242: Component view [Hardware Configuration Access, NetPro Access, S7 Program, Blocks Folder, Charts Folder, Sources]
- Module 243: Process object view [POV, Mass Engineering, Filter Criteria, Replace in Selection, Export/Import POV, I/O Signal Assignment]
- Module 244: Technological list editor [Technological List Editor (TLE), Bulk Engineering, Signal List, Advanced ES, Logic Matrix]
Course 250: MASTER DATA LIBRARY
Course 260: PROJECT LANGUAGE
Course 270: PROJECT BACKUP
Course 280: EXERCISE
Category 300: AS-OS Communication 3
Course 310: INTRODUCTION
Course 320: SOFTWARE TOOLS FOR PLANT BUS CONFIGURATION
Course 330: CONFIGURATION INSTRUCTION
- Module 331: Presettings in the communication settings [Set PG/PC Interface, ISO Ind. Ethernet, TCP/IP, S7ONLINE, Access Point]
- Module 332: Properties of the PC station [SIMATIC PC Station, Computer Name, WinCC Application, Application Reference]
- Module 333: Inserting a network card as an object in HW Config [CP 1623, CP 1613, IE General, Hardnet vs Softnet, MAC Address, IP Address, Subnet Mask]
- Module 334: The "PC station configure" function [Station Configuration Editor, Component Configurator, Index assignment, XDB file, Import Station]
- Module 335: Configuring AS-OS communication in NetPro [Network Configuration, S7 Connection, High Availability Connection, Named Connections, Connection Partner, Local ID]
- Module 336: Downloading a PC station [Download to PC Station, Station Configurator Download, Reload Connection, Target Station]
- Module 337: Downloading an AS [Download HW Config, Download NetPro, Save and Compile, System Data Blocks (SDB)]
- Module 338: Checking the station configuration editor [Commissioning PC Station, Station Status, Connection Status, Pencil Icon, Run/Stop state]
- Module 339: Checking the communication to the AS [Ping, NCM S7 Diagnostics, Special Diagnostics, Connection Status Online]
Course 340: COMMUNICATION WITH THE SIMATIC PLCSIM SOFTWARE
Course 350: EXERCISE
Category 400: Creating PCS 7 Projects - Getting Started 4
Course 410: INTRODUCTION
Course 420: ENGINEERING A PCS 7 PROJECT
- Module 421: Global settings [Customize Plant Hierarchy, Number of hierarchy levels, OS Area determination, Message generation settings]
- Module 422: Hardware configuration [HW Config, Catalog Profile, Drag and Drop, Consistency Check, Save and Compile]
- Module 423: Plant hierarchy (PH) [Creating Folders, Assigning OS, AS-OS Assignment, Deriving Picture Hierarchy]
- Module 424: Creating CFCs [Insert CFC, Rename CFC, Chart Partition, Predecessor for Insertion, Runtime Group]
- Module 425: Creating SFCs [Insert SFC, SFC Editor, Step and Transition, Sequencer Topology]
- Module 426: Block icons and faceplates [Create/Update Block Icons function, Deriving Block Icons from PH, @PCS7Typicals, @TemplateAPL]
- Module 427: The "Compile OS" function [Compile OS Wizard, Scope of Compilation, Tags and Messages, S7 Program Mapping]
- Module 428: OS engineering [Opening WinCC Explorer, OS Project Editor, Graphics Designer, Tag Management, User Administrator]
- Module 429: OS runtime [WinCC Runtime, Activate Runtime, Autostart, Runtime Language, Start Picture]
Course 430: EXERCISE
Category 500: Automation Station 5
Course 510: HARDWARE CONFIGURATION – FIRST STEPS
Course 520: AUTOMATION SYSTEM S7-400 IN PCS 7
- Module 521: S7-400 CPU design [S7-400H, CPU 410-5H, Switch CRES, LED indicators, IF slots, PN/DP interface]
- Module 522: CPU memories [Work Memory (Code/Data), Load Memory (RAM/FEPROM), Retentive Memory, System Memory, Memory Card]
- Module 523: Rack [UR1, UR2, UR2-H, CR3, Rack ID, Backplane Bus, Slot numbering]
- Module 524: CPU software structure [Operating System, User Program, Priority Classes, Process Image Input/Output, Local Data Stack]
- Module 525: Organization blocks [OB1 (Cyclic), OB3x (Cyclic Interrupt), OB8x (Faults), OB100 (Warm Restart), OB121 (Programming Error), OB122 (I/O Access Error)]
- Module 526: Module information [Ctrl+D, Diagnostic Buffer, Cycle Time Statistics, Stack usage, Performance data]
- Module 527: Setting the CPU object properties [Cycle/Clock Memory, Protection Level, Time Synchronization, Diagnostics/Clock, Cyclic Interrupts]
Course 530: PROFIBUS
- Module 531: Brief introduction [Process Field Bus, IEC 61158, Token Passing, Master-Slave, Mono-master vs Multi-master]
- Module 532: PROFIBUS DP basics [Decentralized Peripherals, RS 485, Baud rate, Segment length, Termination resistor]
- Module 533: PROFIBUS Medium Access Protocol [Layer 2, FDL, Token Rotation, SAP Service Access Point]
- Module 534: PROFIBUS DP communication profile [DP-V0 (Cyclic), DP-V1 (Acyclic), DP-V2 (Isochronous/Slave-to-Slave), DPV1 Interrupts]
- Module 535: Device communication and engineering via GSD and EDD [GSD File, Electronic Device Description (EDD), PDM, Device integration, Hardware Catalog update]
- Module 536: Configuring PROFIBUS DP in the Hardware Config [DP Master System, Insert DP Slave, PROFIBUS Address, Watchdog, Prm-Telegram]
Course 540: DISTRIBUTED I/OS
- Module 541: Structure and components of ET 200M [IM 153-1, IM 153-2, Bus Module, Active Backplane, Power Supply, DIN Rail]
- Module 542: Features of ET 200M [H-System support, Time Stamping, CiR support, Hot Swapping, Diagnostics]
- Module 543: Time stamping with ET 200M [1ms accuracy, Sequence of Events (SoE), IM 153-2 high feature, Time synchronization]
- Module 544: Redundant IO signal with the ET 200M [Redundant IM, Redundant Signal Modules, MTA Marshalled Termination Assemblies, Depassivation, Qadr]
- Module 545: Signal modules [SM 321 (DI), SM 322 (DO), SM 331 (AI), SM 332 (AO), Wire break detection, Short circuit detection]
- Module 546: Configuring decentralized peripheral devices in PCS 7 [HW Config Drag and Drop, Object Properties, Measuring range, Interrupt limits]
- Module 547: Process image [PII (Input), PIO (Output), Direct I/O Access (L PEW, T PAW), Consistency]
- Module 548: What are process images? [OB1 Process Image, Partial Process Image (PIP), PIP assignment to OB]
- Module 549: Symbolic names [Symbol Table, Global Symbols, Address assignment, Edit Symbols, Import/Export Symbols]
Course 550: DRIVERS
- Module 551: Channel blocks for signals [Pcs7DiIn, Pcs7AnIn, Pcs7DiOu, Pcs7AnOu, FbAnIn, FbAnOu, Raw value, Simulation]
- Module 552: Driver blocks for modules [Generate Module Drivers, MOD_1, MOD_D1, MOD_CP, OR_M_16, DIAG_AB, Maintenance State]
- Module 553: CPU robustness [CPU_RT, Stop avoidance, OB80 handling, Load shedding, Cycle time monitoring]
Course 560: CONFIGURATION CHANGES IN RUN MODE (CIR)
- Module 561: CiR concept [Configuration in Run, Modification without Stop, CiR Synchronization Time, Plant availability]
- Module 562: Hardware configuration using CiR [Adding DP Slaves, Adding PA Devices, Re-parameterizing modules, Adding I/O modules]
- Module 563: Procedure in hardware configuration using CiR [Download to Station > Download in RUN, Checking CiR capability]
- Module 564: Properties of CiR object and module [CiR Element in HW Config, Guaranteed CiR memory, Calculation of modification time]
- Module 565: CiR rules [Changes allowed in CiR, Changes requiring STOP, H-CiR vs Standard CiR]
Course 570: CONNECTING PROFIBUS PA
Course 580: CONNECTING FOUNDATION FIELDBUS
Course 590: EXERCISE
Category 600: Continuous Function Chart - CFC 6
Course 610: BLOCK CONCEPT
- Module 611: FB, FC, BOP [Function Block (FB), Function (FC), Basic Operations (AND/OR), Basic Instructions, Instance DB, Memory requirements]
- Module 612: Block type [Type definition, FB attributes, S7_m_c, S7_tasklist, Message configuration]
- Module 613: Block instance [Call structure, DB number, Instance specific data, Parameter assignment]
- Module 614: Multi-instance blocks [Multi-instance DB, STAT variable, Aggregation, Reduced DB count]
- Module 615: Process objects AS RT PO license [PO counting rules, Booked POs, CPU 410 SEC, Licensing limits, Stop condition]
- Module 616: Central modification and updating of block types [Update Block Types wizard, Download changes, Interface change, Version management]
- Module 617: "Clean Up" function [Options > Block Types > Clean Up, Removing unused blocks, Compressing User Program, Reorganizing]
- Module 618: Hiding standard libraries [CFC Settings, Library Management, Filter definitions, Preventing misuse]
- Module 619: Organization blocks [Runtime Groups, OB30-OB38, Execution order, Predecessor/Successor, Phase Offset, Optimize Run Sequence]
- Module 6110: Runtime properties of blocks [Installation Pointer, Sampling Time, Turn-down ratio, Reduction ratio]
Course 620: CFCs
- Module 621: Chart I/Os ("chart in chart") [Chart Inputs/Outputs, Nested Charts, Hierarchical Charts, Top Chart, Chart-to-Chart connection]
- Module 622: Compiling a CFC as block type ("chart in block") [Compile as Block, F-Chart to Block, Reusable logic, Custom block creation]
- Module 623: Trend display [CFC Trend, Live Monitoring, Adding variables to trend, Sampling interval, Recording]
- Module 624: Dynamic display [Watch Mode, Test Mode, Tooltips, Value display, Status display]
- Module 625: Test modes [Process Mode, Laboratory Mode, Debugging, Breakpoints (SCL), Force values]
- Module 626: Textual interconnection [Textual Reference, Unresolved interconnection, Close textual interconnections, Global operands, Path reference]
- Module 627: Engineering units [S7_unit, Unit attribute, Scaling, Analog value representation]
- Module 628: Shared Declarations [Enumerations, Units, Equipment Properties, Global declarations, Attribute inheritance]
- Module 629: Cross-references [Chart Reference Data, Address Cross Reference, Go To Location, Jump to Chart]
- Module 6210: Version identifier [Block Version, Chart Version, Project Version, Version comparison]
- Module 6211: Write protection [Chart protection, Function Rights, Read-only mode, User Permissions]
- Module 6212: CPU comparison [Compare Blocks, Online vs Offline, Path comparison, Timestamp comparison, Code comparison]
- Module 6213: Forcing of interconnected inputs [Forcing, Simulation, Deblocking, Force Value, Active Force]
- Module 6214: Selective download [Download Changes Only, Download Selected Charts, Download to Test CPU]
- Module 6215: Representation of new objects and changed parameters [Blue markers, Change tracking, Visual comparison]
Course 630: GENERAL BLOCK FUNCTIONS
- Module 631: Basic Library [PCS 7 Basis Library, Channel Drivers, Diagnostic Blocks, Mathematical Blocks]
- Module 632: Advanced Process Library (AP Library) [PCS 7 APL, APL Structure, Mode Settings, Error Handling, Feature Bits, OS_Perm]
- Module 633: Block I/O structures and Signal Status (ST) [Struct Value/Status, Quality Code, 16#80 (Good), 16#00 (Bad), 16#60 (Simulation), Graying out]
- Module 634: Structures and effect of the Signal Status (ST) [Worst Signal Status, Status Propagation, Faceplate Indication, Color Status]
- Module 635: Feature parameter [Feature.Bit, Customizing block behavior, Enabling/Disabling functions]
- Module 636: Modes of the APL blocks [Manual, Automatic, Local, Out of Service, Program Mode, Operator Mode]
- Module 637: Interlock functions [Intlk02, Intlk04, Intlk08, Intlk16, Bypass, Reset, First-In detection]
- Module 638: Messages and message configuration [ALARM_8P, MsgEvId, MsgFilter, Message Class, Message Type, Associated Values, Event ID]
Course 640: OS APL FACEPLATE
- Module 641: Faceplate design [APL Structure, Toolbar, Overview Window, Standard View, Parameter View, Memo View, Batch View]
- Module 642: Display and control elements [Analog Value Display, Bar Graph, Binary Indicator, Checkbox, Radio Button, Slider]
- Module 643: Status displays, additional information, step functions [Limit Status, Signal Status, Interlock Status, Invalid Signal, Bad Quality]
- Module 644: Commands / mode selection [Switching Modes, Resetting, Setpoint Change, Internal/External Setpoint]
- Module 645: Activating additional functions in the faceplate [Feature bits for views, Trend View activation, Memo View activation]
- Module 646: Displays in the preview [Preview View, Future Status, Permission Preview, Block constraints]
Course 650: TECHNOLOGICAL BLOCKS
- Module 651: Interlock block [Intlk02, Intlk16, Logic (AND/OR), Bypass, First-in detection, Faceplate status]
- Module 652: MotL block [Motor Large, Motor Protection, Feedback Monitoring, Local Control, Rapid Stop, Start/Stop delay]
- Module 653: VlvL block [Valve Large, Valve Analog, Position Feedback, TorqOpen, TorqClose, Open/Close delay]
- Module 654: Dosing block [DoseL, Flow Dosing, Setpoint Quantity, Pause Dosing, Dribbling, Weighing]
- Module 655: PIDConL controller [PID Control Large, Proportional, Integral, Derivative, Setpoint Tracking, Bumpless Transfer, Anti-windup]
Course 660: EXERCISE
Category 700: PROFINET 7
Course 710: INTRODUCTION
- Module 711: Process automation requirements for the fieldbus [Real-time communication, Determinism, High availability, Safety Integrated, Configuration in Run]
- Module 712: PROFINET as a fieldbus [Industrial Ethernet, Switched Ethernet, Full Duplex, 100 Mbps, IEEE 802.3, VLAN]
- Module 713: Terms and Settings PROFINET vs. PROFIBUS [GSDML vs GSD, Device Name vs Address, SNMP, LLDP, MAC Address, IP Address]
Course 720: OVERVIEW OF PROFINET FUNCTIONALITIES IN SIMATIC PCS 7
Course 730: SYSTEM CONNECTIONS
- Module 731: Single PROFINET configuration S1 [System Redundancy S1, Single Controller Single Device, Standard PROFINET]
- Module 732: Media redundancy with MRP [Media Redundancy Protocol (MRP), Ring Topology, Redundancy Manager, Redundancy Client, Recovery Time]
- Module 733: System redundancy S2 [System Redundancy S2, H-System PROFINET, NAP (Network Access Point), Logical Connection]
- Module 734: Redundant PROFINET configuration R1 [System Redundancy R1, Redundant Interface, R1 Devices, Double Head Interface]
- Module 735: Configuration in Run – CiR [PROFINET CiR, TCiR (Type Change in Run), Adding Devices in RUN, Parameter change in RUN]
- Module 736: High-precision time stamping [SoE PROFINET, PTCP, IRT, 1ms accuracy, Time synchronization]
- Module 737: PA ready [PROFINET to PA, PA Profile 4.0, CFU PA, Proxy concept]
Course 740: HARDWARE FOR USING PROFINET IN SIMATIC PCS 7
- Module 741: AS 410 automation system [CPU 410-5H PN, Integrated PN IO interface, 2-port switch, S7-410]
- Module 742: Distributed I/O [ET 200SP HA, ET 200M PN, ET 200SP PN, BusAdapter, Server Module]
- Module 743: Compact Field Unit – CFU PA [SIMATIC CFU, Plug and Produce, Auto-addressing PA, DIQ, PROFINET IO]
- Module 744: Recommended SCALANCE switches [SCALANCE XC-200, SCALANCE XP-200, SCALANCE XF-200, Switch Configuration, Load Class]
- Module 745: Service Bridge [Separate Plant Bus and Terminal Bus, Network Segmentation, VLAN configuration]
- Module 746: Y-Switch (XF204-2BA DNA) [Y-Switch PROFINET, S2 to S1 conversion, R1 to S1 adapter, DNA (Dual Network Adapter)]
- Module 747: IE/PB LINK PN IO [PROFINET to PROFIBUS Gateway, DP Slave on PN Master, Proxy]
Course 750: BLUEPRINTS – RECOMMENDED PROFINET NETWORK CONFIGURATIONS
Course 760: STRUCTURE AND CONFIGURATION OF A PROFINET NETWORK
- Module 761: Component and Network Structure [Network Planning, SINETPLAN, Cable Guidelines, Load Calculation, Update Time]
- Module 762: PROFINET IO-System Configuration [HW Config PROFINET, Assigning IO Controller, Insert PROFINET IO System, Subnet assignment]
- Module 763: I/O Modules Configuration of the ET 200SP HA Station [Configuring ET 200SP HA, Terminal Blocks, Color Coding, Slot Rules, Potential Groups]
- Module 764: ET 200SP HA and CFU Assign Device Name [PST Primary Setup Tool, Assign Device Name, MAC Address Mapping, DCP (Discovery and Configuration Protocol)]
- Module 765: Motor Control via ET 200SP HA Modules [ET 200SP Motor Starter, F-Motor Starter, Direct Starter, Reversing Starter]
- Module 766: Temperature detection using CFU [CFU DIQ, PA Sensor Configuration, Temperature Transmitter, Profile 3.0/4.0]
- Module 767: Increase availability with MRP [Configuring MRP Domain, MRP Manager Role, MRP Client Role, Watchdog Time]
- Module 768: Topology Configuration [Topology Editor, Port Interconnection, Partner Port, Cable Length, Fiber Optic]
- Module 769: Reset to factory settings [Reset PN Device, Factory Reset via MAC, Reset to Factory Defaults]
Category 800: Sequential Control - SFC 8
Course 810: INTRODUCTION
Course 820: PRINCIPLES OF THE SFC
- Module 821: Operating states [SFC States, Ready, Active, Completing, Held, Aborted, Error, Paused, Resuming]
- Module 822: Sequence paths of an SFC [Sequencer, Start Condition, Transition Logic, End of Sequence]
- Module 823: Phases of a step [Initialization (S1), Processing (S2), Termination (S3), Action types]
- Module 824: Executing steps and transitions [Step Logic, Transition Condition, Step Time Monitoring, Confirmation]
- Module 825: Execution of a parallel sequence [Simultaneous Branches, Synchronization, AND Divergence, AND Convergence]
- Module 826: Execution of an alternative sequence [Alternative Branches, OR Divergence, Priority Rules, OR Convergence]
- Module 827: Execution of a loop [SFC Loop, Jump Back, Cycle Counter, Termination Condition]
- Module 828: Execution of a jump [Jump to Step, Direct Jump, Destination Step, Resume after Jump]
Course 830: SFC
Course 840: SFC TYPE
- Module 841: Creating an SFC type [SFC Type Editor, Interface Sequencer, Characteristics, Type-Instance Model]
- Module 842: Characteristics of an SFC type [Control Strategies, Setpoints, Process Values, Block Contacts, Control Values, Note Texts]
- Module 843: SFC type faceplate [SFC Faceplate, Step Display, Control Strategy Selection, Allocation Status, Setpoint View]
Course 850: EXERCISE
Category 900: Process Tag Type, Model, Master Data Library, and Process Object View 9
Course 910: INTRODUCTION
Course 920: PROCESS TAG TYPE OR MODEL
Course 930: PROCESS TAG TYPES AND PROCESS TAGS
- Module 931: Motor type chart [Template Chart, Assigning Parameters, I/O Linking, S7_m_c, Message Configuration]
- Module 932: Creating a process tag type [Create Process Tag Type Wizard, Define Import/Export Points, Template creation]
- Module 933: Creating an import file for the process tag type [IEA Import Export Assistant, .IEA File Format, CSV Export, Parameter selection]
- Module 934: Process tag data files in the IEA File Editor [Editing IEA Files, Assigning Symbols, Parameter Assignment, Row/Column editing]
- Module 935: Importing process tags [Import/Export Assistant, Generating Charts, Log File, Overwrite options]
- Module 936: External editing of process tags [Excel Editing, Bulk Data Modification, Re-import, CSV manipulation]
Course 940: MODEL AND REPLICAS
Course 950: THE MASTER DATA LIBRARY
- Module 951: PCS 7 libraries [Blue Library, Standard Library, Project Library, Master Data Library (MDL)]
- Module 952: Own blocks [FB Storage, FC Storage, User Defined Blocks, FB/FC Number Ranges]
- Module 953: Other libraries [Industry Library (IL), Condition Monitoring Library (CML), Minerals Library]
- Module 954: Managing libraries [Library Versioning, Cleaning Library, Archiving Library, Path management]
Course 960: PROCESS OBJECT VIEW (PO VIEW)
- Module 961: "General" tab [POV General, Object Name, LID, Author, Description, Hierarchical Path]
- Module 962: "Parameters" tab [POV Parameters, Bulk Parameterization, Block I/O, Value modification]
- Module 963: "Signals" tab [POV Signals, I/O Assignment, Signal Comments, Symbol Table integration]
- Module 964: "Messages" tab [POV Messages, Message Priorities, Message Text Bulk Edit, Event ID]
- Module 965: "Picture objects" tab [POV Picture Objects, Block Icon Assignment, Picture Navigation, Jump target]
- Module 966: "Archive tags" tab [POV Archive Tags, Archiving Settings, Acquisition Cycle, Archiving Cycle]
- Module 967: "Charts" tab [POV Charts, Chart Comments, Chart Version, Block Type info]
- Module 968: Working with the process object view [POV Filter, POV Search/Replace, Export to Excel, Import from Excel, Select All]
Course 970: EXERCISE
Category 1000: OS and Graphics Design 10
Course 1010: OS
- Module 1011: Operator Station [WinCC Explorer, OS Structure, Master Control Console (MCP), OS Server, OS Client]
- Module 1012: OS project type [Single User Project, Multi-User Project, Client Project, Server Project, Redundant Server]
- Module 1013: Target OS and Symbolic computer name [Simatic Shell, Target Path, Computer Name Configuration, Redundancy path]
- Module 1014: OS project data generated in SIMATIC Manager [AS-OS Engineering, Mapping Tags, Server Data, Named Connections]
- Module 1015: Central OS Settings [Lifebeat Monitoring, Time Synchronization, User Administrator, Audible Alarm]
- Module 1016: OS Project Editor [Screen Resolution, Layout Configuration, Message System Setup, Basic Data, @PDL]
- Module 1017: OS Multi-User Engineering [WinCC Autostart, Remote Configuration, Concurrent Engineering, Project Duplicator]
Course 1020: GRAPHICS DESIGNER
- Module 1021: Password protection for PDLs [VBA Password, Picture Protection, Access Control, Edit protection]
- Module 1022: Graphics libraries [SVG Library, Global Library, Project Library, Industrial Graphic Library]
- Module 1023: Basic handling and the Properties dialog [Object Properties, Events, Attributes, Geometry, Colors]
- Module 1024: Central Color Palette [Color Palette Configuration, Global Color Scheme, Day/Night Switching, Color Index]
- Module 1025: Smart Objects [I/O Field, Bar, Status Display, Faceplate Instance, OLE Element, Control]
- Module 1026: Windows Objects [Button, Checkbox, Slider, Connector, Rectangle, Polygon]
- Module 1027: Making graphics dynamic [Dynamic Dialog, C-Script, VBScript, Direct Connection, Trigger]
Course 1030: DYNAMIC WIZARDS
Course 1040: CUSTOMIZED GRAPHIC OBJECTS AND PROTOTYPES
- Module 1041: Steps for creating a customized object [Grouping Objects, Custom Properties, Events Mapping, Property Topics]
- Module 1042: Steps for creating a prototype from a customized object [UDO User Defined Object, Type Change, Master Copy]
- Module 1043: Making a customized object [Configuration Dialog, Interface Definition, Attributes/Events connection]
Course 1050: CUSTOMIZED BLOCK ICONS AND FACEPLATES
- Module 1051: Block icons and the @PCS7TypicalsAPLV8.pdl template picture [Typicals File, Block Icon Generation, Type Attribute, Server Data]
- Module 1052: Block icons and @PCS7TypicalsXYZ.pdl template pictures [Custom Typicals, Naming Convention, Auto-generation rules, Versioning]
- Module 1053: Update block icons that include user-defined customizations [Update Wizard, Preserve Custom Changes, Reset to Original]
- Module 1054: Block icons from the @TemplateAPLV8.pdl picture [Template Picture vs Typicals, Manual Placement, Linking to Tag]
- Module 1055: Folder for custom pictures [GraCS, Project Folder Structure, Server Data, Publish Pictures]
Course 1060: FACEPLATES IN PCS 7 V8
- Module 1061: APL Styleguide [APL Design Principles, Color Scheme, Ergonomics, Grid Layout, 3D Effects]
- Module 1062: @PCS7ElementsAPL.PDL [Faceplate Elements, Analog Display, Status Display APL, Button APL]
- Module 1063: Generating a replica from existing faceplates [Save As, Faceplate Designer, Customizing Faceplate, Binding Tags]
Course 1070: TEXT- AND GRAPHICS LIST EDITOR
Course 1080: EXERCISE
Category 1100: Archiving System 11
Course 1110: INTRODUCTION
Course 1120: TAG LOGGING
- Module 1121: Tags [Archive Tags, Process Tags, Internal Tags, Tag Supply]
- Module 1122: Cycles [Acquisition Cycle, Archiving Cycle, Factor, Offset]
- Module 1123: Archiving methods [Fast Tag Logging, Slow Tag Logging, Event-controlled, Compressed Archive]
- Module 1124: Tag Logging Configuration [Archive Wizard, Database Segments, Backup Configuration, MDF/LDF files, Signing]
- Module 1125: WinCC OnlineTrendControl [Trend View, Ruler, Zoom, Export Data, Statistics, Time Range]
- Module 1126: WinCC FunctionTrendControl [f(x) Trend, XY Plot, Setpoint vs Actual, Hysteresis]
- Module 1127: WinCC OnlineTableControl [Table View, Historical Data List, Export to CSV, Print Table]
Course 1130: MESSAGES
- Module 1131: PCS 7 messages [OS Messages, AS Messages, System Messages, Process Control Messages]
- Module 1132: Message concepts [Message Blocks, Message Class, Message Type, Message Group, Hiding Messages]
- Module 1133: Message Display with WinCC AlarmControl [Alarm Logging, Short-term Archive, Long-term Archive, Message List, Hit List]
- Module 1134: Alarm help [Info Text, Loop-in-Alarm, Alarm Documentation, HTML Help]
- Module 1135: Configuring the Horn [Horn Editor, Audible Alarm, Signal Module, Sound File (.wav), Acknowledge Tag]
Course 1140: PROCESS HISTORIAN (PH)
- Module 1141: Overview of the Functions [Central Archiving, Long-term Storage, SQL Server, Scalability, Redundancy]
- Module 1142: Information Server [Web-based Reporting, IS Dashboard, Report Subscription, Email delivery]
- Module 1143: Microsoft Reporting Services [SSRS, Report Builder, Custom Reports, Data Source, Dataset]
Course 1150: EXERCISE
Category 1200: Reporting, Printing and OS User Administration 12
Course 1210: REPORTING AND PRINTING
- Module 1211: Basics [Report Designer, Page Layout, Line Layout, RPL File, LPL File]
- Module 1212: Printers included in the PCS 7 system architecture [Line Printer, Alarm Printer, Report Printer, Print Server]
- Module 1213: Configuring a message sequence report on a client [Message Sequence Report, Line Based Report, Serial Interface]
- Module 1214: Configuring a report with page layout [Page Layout Editor, Header and Footer, Dynamic Objects, Static Objects]
- Module 1215: Planning a print job [Print Job Configuration, Time-driven Trigger, Event-driven Trigger, Cycle Trigger]
- Module 1216: Manual activation of a trend report [Print Button, C-Script Printing, Report Runtime, PrintJob(), Hardcopy]
Course 1220: PCS 7 OS USER ADMINISTRATION
- Module 1221: Standard PCS 7 authorization levels [User Rights, Permission Levels, Level 1 to 1000, Hierarchy Levels]
- Module 1222: Adding a new user [User Administrator, User Groups, Password Policy, Auto-Logoff]
- Module 1223: Description of authorization levels for PCS 7 [Monitoring (1), Process Controlling (5), Higher Process Controlling (6), Administration]
- Module 1224: Instance-specific parameterization [Block Icon Permission, Area Specific Rights, Instance granularity]
- Module 1225: PCS 7 system buttons and associated authorization levels [System Area, Button Permissions, User Admin Button, Runtime Exit]
- Module 1226: Operator authorization for the locking of messages in the faceplate [Message Locking, Lock Permission, Level 1100, Maintenance]
- Module 1227: Extension of authorization levels [Custom Authorization, Scripting Permissions, User Defined Levels]
- Module 1228: User authorization for graphic objects [Object Permission, Visible/Invisible by User, Enabled/Disabled by User]
- Module 1229: Login with chip cards [Chip Card Reader, Smart Card Login, UID, Card Writer]
- Module 12210: SIMATIC Logon and PCS7 OS user authorization [Windows User Integration, Active Directory, Central User Management, Domain Controller]
Course 1230: EXERCISE
Category 1300: OS Server, Client, Redundancy and Project Download 13
Course 1310: OS SERVER AND REDUNDANCY
- Module 1311: OS Redundancy within the PCS 7 OS [Redundancy Partner, Serial Cable, Network Redundancy, WinCC Redundancy]
- Module 1312: Start-up of an OS server [Project Activation, Redundancy Synchronization, Archives Sync, User Archives Sync]
- Module 1313: The redundancy principle [Database Synchronization, Archive Synchronization, Master/Standby, Fault tolerance]
- Module 1314: Configuration of redundant OS servers [Redundancy Editor, Path Configuration, Health Check, Default Master]
Course 1320: CLIENT
- Module 1321: Client architecture [Multi-client, Standard Client, Server Data Package, View only client]
- Module 1322: Client switch-over and permanent operability [Preferred Server, Automatic Switchover, Redundancy State]
- Module 1323: Configuration of a client [Assigning Server Data, Simatic Shell, Standard Server, Package loading]
Course 1330: PROJECT DOWNLOAD
Course 1340: OS SIMULATION
Course 1350: EXERCISE
Category 1400: Multi-User Project Engineering 14
Course 1410: MULTI-USER PROJECT ENGINEERING
Course 1420: MULTIPROJECT ENGINEERING
Course 1430: A CASE STUDY FOR A MULTIPROJECT
- Module 1431: Creating a new multiproject [New Project Wizard, Multiproject Container, Add Project]
- Module 1432: Project structure and plant hierarchy [Cross-project Hierarchy, Update PH, OS Area propagation]
- Module 1433: Automation stations [AS Assignment, Hardware Configuration in MP, Station naming]
- Module 1434: Operator stations [OS Assignment, Server Assignment, OS Reference]
- Module 1435: Assignment of automation systems [Cut and Paste AS, Project Reference, Moving Stations]
- Module 1436: Assignment of operator stations [Cut and Paste OS, Reference OS, Moving OS]
- Module 1437: Cross-project communication on the system bus [S7 Connection Cross-project, Merging Subnets, Connection Table]
- Module 1438: AS-OS communication [Compile OS Cross-project, NetPro Merge, S7 Programs in different projects]
- Module 1439: AS-AS communication [AS-wide Interconnections, S7 Communication, Inter-project blocking]
- Module 14310: Synchronizing the Shared Declarations [Update Shared Declarations, Unit Merging, Enumeration Sync]
- Module 14311: Distributing the projects [Save As with Reorganization, Remove for Editing, Remote Engineering]
- Module 14312: Integrating projects [Add to Multiproject, Update View, Re-integrate]
- Module 14313: OS compilation [Compile OS from MP, Selecting S7 Programs, Scope of compile]
- Module 14314: Archiving and merging projects [Archive Multiproject, Retrieve Multiproject, Span disks]
Course 1440: MULTI-USER ENGINEERING
Course 1450: EXERCISE
Category 1500: Control Module Types 15
Course 1510: CONTROL MODULE TYPES
Course 1520: CONTROL MODULE TYPE BY MEANS OF AN EXAMPLE
Course 1530: OUTLOOK: EQUIPMENT MODULE TYPES
Open a whole world of education
Start Learning Today
Unlock new skills and opportunities. Each course opens a world of practical knowledge that can elevate your career.
Students come first
Every decision puts students at the center. Your needs guide our courses, tools, and support.
Commitment & Dedication
We’re committed to empowering learners and making a real impact. Your growth is our mission.
Continuous Learning & Respect
We believe in constant improvement and lifelong learning. We act with respect and aim to create the greatest positive impact.
Learning programs (soon)
Train your team and upgrade your plant performance
Train your engineers to solve real automation problems
WITHOUT taking entire shifts offline for long classroom sessions WITHOUT relying on outside integrators for every minor issue
WITH a skilled internal team capable of maintaining PCS 7, Profinet, and plant networks
WITHOUT taking entire shifts offline for long classroom sessions WITHOUT relying on outside integrators for every minor issue
WITH a skilled internal team capable of maintaining PCS 7, Profinet, and plant networks
Automation
Strengthen your workforce and stabilize operations
WITHOUT overtime costs, travel expenses, or lost production
WITHOUT months of onboarding or complex vendor coordination
WITH immediate improvements in troubleshooting speed and plant reliability
WITHOUT overtime costs, travel expenses, or lost production
WITHOUT months of onboarding or complex vendor coordination
WITH immediate improvements in troubleshooting speed and plant reliability
Operations & Maintenance
Develop your people while optimizing cost and performance
WITHOUT large training budgets or multi-day offsite programs
WITHOUT downtime risk or sacrificing operational continuity
WITH clear financial impact through reduced downtime and increased self-sufficiency
WITHOUT large training budgets or multi-day offsite programs
WITHOUT downtime risk or sacrificing operational continuity
WITH clear financial impact through reduced downtime and increased self-sufficiency
Executive / Leadership
Great offer today!
50% OFF - Coming soon.. - Use promo code #TU50
